Manninen, T; Riihela, A; Heidinger, A; Schaaf, C; Lattanzio, A; Key, J (2018). Intercalibration of Polar-Orbiting Spectral Radiometers Without Simultaneous Observations. IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 56(3), 1507-1519.
Abstract
A new intercalibration method for two polarorbiting satellite instruments or two instrument constellations' Fundamental Climate Data Records (FCDRs) is presented. It is based on statistical fitting of reflectance data from the two instruments covering the same area during the same period, but not simultaneously. A Deming regression with iterative weights is used. The accuracy of the intercalibration method itself was better than 0.5% for the Moderate Resolution Imaging Spectroradiometer (MODIS) versus MODIS and Advanced Very High Resolution Radiometer (AVHRR) versus AVHRR test data sets. The intercalibration of an AVHRR FCDR generated by NOAA versus a combined MODIS Terra and Aqua data set of red and near-infrared (NIR) channels was carried out and showed a difference in the reflectance values of about 2% (red) and 6% (NIR). The presented intercalibration method can be used for checking the calibration of two instruments or FCDRs in all viewing angles used separately.
DOI:
10.1109/TGRS.2017.2764627
ISSN:
0196-2892